检测哮喘患者呼出气冷凝液中氮氧化物作为呼出气一氧化氮检测的一项补充:横断面研究

2011/08/12

   摘要
   背景:将检测肺生物标志物 [如分析呼出气冷凝液(EBC)]作为一种无创手段,为研究哮喘病理生理学提供了一种有效的手段。虽然近期诸多试验均对这些方法进行了研究,但在方法学上存在不一致性。本研究的第一阶段旨在验证收集、储存和分析EBC的方法,第二步将分析EBC氮氧化合物(NOx)是否可以作为哮喘患者呼出气一氧化氮(FeNO)检测的一个补充。
   方法:此项以医院为基础的横断面研究入选23名哮喘患者和与之匹配的23名对照受试者。检测EBC中NOx和FeNO及肺功能。通过检测10名健康受试者EBC中NOx,评价检测之间和患者之间的可重复性。
   结果:检测之间的可重复性组间相关系数(ICC)很好,患者间的可重复性(Fermanian分类)ICC中等程度。哮喘患者NOx水平 [几何平均值(IQR)14.4uM(10.4 - 19.7)]显著高于对照[9.9uM(7.5 - 15.0)],哮喘患者FeNO [29.9 ppb(17.9 - 52.4)]高于对照[9.6 ppb(8.4 - 14.2)]。随着哮喘严重程度增加,FeNO显著增加。
   结论:我们证实了检测EBC中NOx的步骤,而且显示该检测方法能为哮喘分析提供有用信息。 

                                                             (林江涛 审校) 
                  BMC Res Notes. 2011 Jun 16;4(1):202. [Epub ahead of print]


Analysis of Nitrogen oxides (NOx) in the Exhaled Breath Condensate (EBC) of subjects with asthma as a complement to exhaled Nitric Oxide (FeNO) measurements: a cross-sectional study.

Cherot-Kornobis N, Hulo S, Edme JL, de Broucker V, Matran R, Sobaszek A.

Abstract
BACKGROUND:
 The study of pulmonary biomarkers with noninvasive methods, such as the analysis of exhaled breath condensate (EBC), provides a useful approach to the pathophysiology of asthma. Although many recent publications have applied such methods, numerous methodological pitfalls remain. The first stage of our study consisted in validating methods for the collection, storage and analysis of EBC; we next sought to clarify the utility of analysing nitrogen oxides (NOx) in the EBC of asthmatics, as a complement to measuring exhaled nitric oxide (FeNO).
METHODS: This hospital-based cross-sectional study included 23 controls matched with 23 asthmatics. EBC and FeNO were performed and respiratory function measured. Intra-assay and intra-subject reproducibility were assessed for the analysis of NOx in the EBC of 10 healthy subjects.
RESULTS: The intraclass correlation coefficient (ICC) was excellent for intra-assay reproducibility and was moderate for intra-subject reproducibility (Fermanian’s classification). NOx was significantly higher in asthmatics (geometric mean [IQR] 14.4uM [10.4 - 19.7] vs controls 9.9uM [7.5 - 15.0]), as was FeNO (29.9ppb [17.9 - 52.4] vs controls 9.6ppb [8.4 - 14.2]). FeNO also increased significantly with asthma severity.
CONCLUSIONS: We validated the procedures for NOx analysis in EBC and confirmed that it provides useful information in our asthmatic population study

BMC Res Notes. 2011 Jun 16;4(1):202. [Epub ahead of print] 


上一篇: 哮喘患者的反复高剂量过敏原吸入激发试验
下一篇: 哮喘患者全身炎症及其对治疗的反应

用户登录